Mitsubishi Heavy Industries — ELECTRICAL SYSTEM

(2) Regulator voltage test (a) Test on a test bench (3) Alternator inspection after disassembly (a) Inspection of each diode Use a fully charged battery. Close the switch, and gradually increase the alternator speed. Make sure that the current is below 5 amperes and the voltage is 14.1 to 14.7 volts when the alternator speed reaches 5000 rpm. If this requirement is nor met, replace the regulator assembly. It is impossible to reset the regulator voltage. Check for continuity between the wire lead and the heat sink. Any continuity, if noted, means that the diode is shorted; no continuity means an open diode.

I I I -"'- I Checking diodes (b) Test on a machine (b) Field coil inspection Connect a voltmeter in the circuit between the terminal L and ground. Turn on the battery switch to make sure that the voltage is 0 (zero). If the voltmeter needle defects, the alternator is defective, or the circuit is misconnected. With the ammeter terminals short-circuited to prevent the starter current from flowing to the ammeter, start the engine. The field coil is in good condition if the resistance between the slip rings is approximately 14.3 ohms at a temperature of 20°C (68°F). If the charging current is below 5 amperes when the engine is running at about 2000rpm, read the voltmeter.

If it exceeds 5 amperes, charge the battery for a while, or replace the battery with a fully charged one. Another method is to connect a 1/4 ohm (25 W) resistor in series with the battery to limit the charging current. The regulated voltage should be 14.1 to 14.7 volts; if not, replace the regulator assembly. Checking field coil Battery switch + Ammeter V Volt meter Battery i r -84-