Komatsu — DURING STORAGE

OPERATION LONG TERM STORAGE LONG TERM STORAGE BEFORE STORAGE NOTICE When storing the machine (1 month or more), set the machine in the posture shown in the diagram on the right to protect the cylinder rod. (To prevent rusting of the cylinder rod) When keeping in long-term storage (more than one month), store as follows. Clean and wash all parts, then store the machine indoors. If the machine has to be stored outdoors, select level ground and cover the machine with a sheet. Completely fill the fuel tank. This prevents moisture from collecting. Lubricate and change the oil before storage. Coat the exposed portion of the hydraulic cylinder piston rod with grease.

Disconnect the negative terminals of the battery and cover it or remove it from the machine and store it sepa- rately. Lock each control lever and pedal with the lock lever and offset lock cover. To prevent corrosion, be sure to fill the cooling system with Supercoolant (AF-NAC) or permanent type anti- freeze (density between 30% and 68%). DURING STORAGE WARNING If it is necessary to perform the rust-prevention operation while the machine is indoors, open the doors and windows to improve ventilation and prevent gas poisoning. During storage, operate and move the machine for a short distance once a month so that a new film of oil will coat moving parts.

At the same time, also charge the battery. When operating the work equipment, wipe off all the grease from the hydraulic cylinder rods. If the machine is equipped with an air conditioner, operate the air conditioner for 3 to 5 minutes once a month to lubricate all parts of the air conditioner compressor. Always run the engine at low idling when doing this. In addition, check the refrigerant level twice a year. 3-119