Mack Trucks — 5-101.bk

5-101.bk Page 8 Friday, March 17, 2006 11:05 AM Restriction Pressure Test The clamp springs must always be located on underside of tube to avoid damaging hood when closed. Perform restriction pressure test at maximum, full-load condition. 4. Reinstall cooler if removed to flush and then pressure-test CMCAC system. A restriction in the internal portion of cooler may interfere with proper airflow, and can result in excessively high pyrometer readings. To perform a restriction pressure test, use the following procedure: 5. If cooler passes restriction and pressure tests, remove test equipment, reinstall inlet and outlet tubes, hoses and clamps or reinstall plugs, if equipped.

Tighten clamps to 38 lb-in (4.3 N m). 1. Units are equipped with connections on the inward sides of inlet and outlet charge cooler tubes. Remove plugs and install pressure gauge lines to begin test. Core Repair 2. Install the appropriate pressure gauge to inlet and outlet charge air cooler tubes. The maximum allowable pressure drop across cooler is 2 psi (13.79 kPa) at full-load condition. Certain types of CMCAC core foreign object impact damage can be field-repaired (depending on extent of damage). Other types, or more extensive damage, cannot be field-repaired and require core replacement. Determining whether or not core damage is repairable is a critical first step.

Proper diagnosis can eliminate costly man hours and keep vehicle downtime to a minimum. If using manometers for this test, the difference between readings should not exceed 4 in-Hg (13.5 kPa). REPAIR PROCEDURES The following guidelines will help you determine which areas are repairable or nonrepairable. 3. If pressure drop is higher than specified amount, remove CMCAC. Flush the inside to remove any deposits that may be present. Do not use caustic cleaners. Be extremely careful when handling cooler so as not to damage core. To ensure the CMCAC system will function properly after repair or replacement, a pressure/ leak test is recommended. Page 8-8 200 ENGINE INSTALLATION & TESTING