Perkins — 1106DO&M2ACOVERTOP43.pdf

SEBU8119-01 26 Operation Section Features and Controls Features and “Warning” Controls 02308958 Monitoring System The “Warning” lamp and the warning signal (orange lamp) turn “ON” and the warning signal is activated continuously in order to alert the operator that one or more of the engine parameters is not within normal operating range. “Warning/Derate” A NWARNING The “Diagnostic” lamp turns “ON” and the warning If the Shutdown mode has been selected and the warning indicator activates, engine shutdown may take as little as 20 seconds from the time the warn- ing indicator is activated. Depending on the application, special precautions should be taken to avoid personal injury.

The engine can be restarted following shutdown for emergency maneuvers, if necessary. NOTICE The Engine Monitoring System is not a guarantee against catastrophic failures. Programmed delays and derate schedules are designed to minimize false alarms and provide time for the operator to stop the engine. Coolant temperature The engine will be derated if the engine exceeds preset operational limits. The engine derate is achieved by restricting the amount of fuel that is available for each injection, The amount of this reduction of fuel is dependent on the severity of the fault that has caused the engine derate, typically up to a limit of 50%.

This reduction in fuel results in a predetermined reduction in engine power. “Warning/Derate/Shutdown” after a shutdown for use in an emergency. « Intake manifold air temperature A shutdown of the engine may occur in as little as 20 seconds. The engine can be restarted after ¢ intake manifold air pressure a shutdown for use in an emergency. However, the cause of the initial shutdown may still exist. The engine may shut down again in as little as 20 Oil pressure seconds. Engine speed/timing Programmable Options Systems Operation begin to flash when the derating occurs. The “Diagnostic” lamp turns “ON” and the warning signal (red lamp) is activated.

After the warning, the engine power will be derated. The engine will continue at the rpm of the set derate until a shutdown of the engine occurs. The engine can be restarted The following parameters are monitored: * signal (red lamp) is activated. After the warning, the engine power will be derated. The warning lamp will If there is a signal for low oil pressure or for coolant temperature, there will be a two second delay in and order to verify the condition. For each of the programmed modes, refer to Troubleshooting Guide, “Indicator Lamps” for more If the Warning/Derate/Shutdown mode has been selected and the warning indicator activates, bring the engine to a stop whenever possible.

Depending on the application, special precautions should be taken to avoid personal injury. The engine can be programmed to the following modes: information on Indicator Lamps. For more information or assistance for repairs, consult your Perkins dealer or your Perkins distributor.