3.6. Long-term storage Operation 3.6. Long-term storage 3.6.1. Before storage When storing the machine for a long time, take the following pre- cautions: After every part is washed and dried, store the machine in a dry building. Never leave it outdoors. If the machine must be left outdoors, park it on well-drained concrete and cover it with canvas, etc. Completely fill the fuel tank, lubricate, and change the oil before storage. Apply a thin coat of grease to the metal surface of the hydrau- lic piston rods. Disconnect the negative terminals of the battery and cover it, or remove it from the machine and store it separately.
If the ambient temperature is expected to drop below 0°C, always add antifreeze to the cooling water. Lock the control lever for working hydraulics in place and apply the parking brake by actuating the toggle switch on the steering column. 3.6.2. During storage If, for any reason, it is unavoidable to perform the rust-pre- vention operation indoors, open the doors and windows to improve ventilation and to prevent gas poisoning. Operate the engine and move the machine over a short distance once a month so that a new film of oil will be applied to movable parts and component surfaces. At the same time, also charge the battery.
Before operating the work equipment, wipe off the grease on the hydraulic piston rod. 3-90 CAUTION CAUTION