Komatsu — After completion of emergency travel operation:

4.3. Towing the machine Troubleshooting 4.3.4. Emergency travel operation The normal gear shifting is carried out by electric signals. If there is a failure in the electrical system and the machine does not move, it is possible to move the machine by using the following procedure: The emergency travel operation is to enable the machine to drive under its own power to the nearest repair shop when there is a failure in the electrical system. This operation must not be used for any other purpose. When performing this operation, always keep the engine stopped except when starting the machine.

When starting the engine, always depress the brake pedal and check that the surrounding area is safe and the machine is in operational condition. NOTE Always request your Komatsu distributor to carry out the emergency travel operation, or consult your Komatsu distrib- utor before carrying it out yourself. Emergency travel operation, when the electrical circuit for gear shifting is inoperationable 1 2 1. Apply the parking brake by actuating the toggle switch on the steering column and move the directional lever to the neutral position. 2. Remove the screw (1) and slide the plate (2) to one side. GK100311 3.

Pull spool (3) in position "F" for 2nd gear forward or push it into position "R" for 2nd gear revers whatever direction is intended. 4. Disconnect all connectors to the transmission control valve. 5. Release lock-nut (5) and tighten the adjustment-screw (4) to the proportional solenoid valve (6) carefully to its stop. 6. Depress the brake pedal, start the engine, then release the parking brake and slowly release the brake pedal to allow the machine to move. After completion of emergency travel operation: 1. For normal operation set the spool (3) to the neutral position.

Install plate (2) and bolt (1) securely to hold it in place as oth- erwise the spool may come out when the machine is travel- ling. 4 5 2. Carefully release adjustment-screw (4) of the proportional solenoid valve (6) up to its stop and secure with lock-nut (5). 6 3. Connect all connectors to the transmission control valve. GK100313 4-8 R N F 3 GK100312