Komatsu — 4.4.1. Precautions for charging the battery

4.4. If battery is discharged Troubleshooting 4.4.1. Precautions for charging the battery Charging with the Battery Installed in the Machine Before charging, disconnect the cable from the negative (-) terminal of the battery. Otherwise, an unusually high voltage will damage the alternator. While charging the battery, remove all battery plugs for a suf- ficient ventilation. To avoid gas explosions, do not bring fire or sparks near the battery. If the electrolyte temperature exceeds 45°C, stop charging for a while. Turn off the charger as soon as the battery is charged. Overcharging the battery may cause the following:

Overheating of the battery Decreasing the quantity of electrolyte Damaging the electrode plate. Do not mix the cables (positive (+) to negative (-) or negative (-) to positive (+)), as this will damage the alternator. When performing any service to the battery besides checking the electrolyte level or measuring the specific gravity, discon- nect cables from the battery. NOTE The batteries are on both sides at the rear of the machine. 4-10