Komatsu — Cleaning or replacing the air cleaner element

Maintenance 5.8. Service procedure 3. Blow dry compressed air (less than 7 bar, 100 psi) through the element from the inside along the grooves, then apply from the outside and again from the inside. AE063670 4. Remove the seal from the outer element after cleaning it. The outer element must be replaced after 6 times of cleaning or after one year of use. Always replace outer and inner ele- ment together. If the dust indicator displays red immediately after the outer element has been cleaned, replace both the inner and outer element, even if the outer element has not been cleaned 6 times.

5 4 Check the inner element mounting nuts for looseness and, if necessary, retighten.Check the inner element mounting nuts for looseness and, if necessary, retighten. AE063680 Replace seal washer (5) or wing nut (4) with new parts if they are broken. NOTE If small holes or thinner parts are found on the element when checking it with an electric bulb after cleaning and drying, replace the element. When cleaning the element, do not hit it or beat it against other objects. Do not use elements with damaged gasket or seal or groove. 5. Reinstall the cleaned element. AE063690 5-23