Maintenance 5.8. Service procedure Cleaning the interior of the cooling system Immediately after the engine has stopped, the coolant is hot and may cause injuries. Allow the engine to cool before draining the water. Since cleaning is performed while the engine is running, it is very dangerous to walk or stand under the machine as the machine may suddenly start moving. Therefore, never go under the machine while the engine is running. Never remove the radiator cap when the engine is at operating temperature as the coolant is under pressure. Boiling water and steam spurting out from the radiator may cause injuries.
Allow the engine to cool until the radiator filler cap is cool enough to be touched with your hand. Remove the filler cap slowly to allow pressure to be relieved. Stop the machine on level ground when cleaning or changing the coolant. Clean the inside of the cooling system change the coolant and replace the corrosion resistor according to the table below. When determining the ratio between antifreeze and water, check the lowest temperature in the past, and mix the compo- nents according to the table below. It is recommended to use a temperature for determining the mixing ratio which is approx. 10°C lower.
5-25 WARNING WARNING Kind of coolant Cleaning inside of cooling system and changing coolant Replacing corrosion resistor Permanent type antifreeze (all season) Every year (autumn) or every 2000 hours, whichever comes first Every 1000 hours, when cleaning the inside of the cooling system and when changing the coolant Non-permanent type anti-freeze containing ethylene glycol (winter, one-season) Every 6 months (spring, autumn) (Drain antifreeze in spring, add antifreeze in autumn) When not using antifreeze Every 6 months or every 1000 hours, whichever comes first