Komatsu — Bucket with bolted-on teeth

5.8. Service procedure Maintenance Replacing the bucket teeth Bucket with bolted-on teeth Any movement of the work equipment when replacing the teeth is extremely dangerous. For this reason the working attachment should be lowered to the ground and the parking brake applied by means of actuating the toggle switch on the steering column. After this, switch the engine off and secure the control lever for the working attachment. When the bucket teeth are worn, replace them as follows: 1. Raise the bucket to a convenient height, and put blocks under the bucket to prevent it from coming down. Raise the bucket so that the bottom is horizontal. 2 2.

Remove the bolt and nuts (1) and (2), then remove bucket tooth (3). 3. Clean the installation surface of bucket tooth (3). 4. Install new teeth to the bucket. If necessary, insert shims so that there is no clearance between the teeth and the top sur- face of the bucket. 3 Block 1 GK100333 NOTE Continue to add shims until it becomes impossible to add a 0.5 mm shim. If the mounting surface is worn, repair it before installing the teeth. 5. To prevent any gap between the teeth and tip of the bucket, tighten bolts and nuts (1) and (2) temporarily, then hit the tip of the teeth with a hammer. Tightening torque of mounting bolt (1):

900 ± 40 Nm (665 ± 30 lbft) Tightening torque of mounting bolt (2): 620 ± 30 Nm (460 ± 22 lbft) 6. After operating the machine for a few hours, retighten the mounting bolts. 5-34 DANGER DANGER