5.8. Service procedure Maintenance Topping up the grease reservoir of the central lubrication system 1. The grease reservoir must be topped up at the latest when the grease level has reached the "Minimum" marking (1). 2. Grease is topped up through the filler nipple (3) on the cover of the grease reservoir using a high-pressure grease gun. 3. Remove the protective cover from the filler nipple (3) on the cover of the grease reservoir. 4. Clean the filler nipple (3) and surrounding area as well as the end of the nozzle of the high-pressure grease gun. 5. Place the nozzle of the high-pressure grease gun on the filler nipple. 6. Switch the ignition on. 7. Activate the high-pressure grease gun.
8. Press button (5) on the pump so that the pump switches on and carries out a lubrication cycle while topping up takes place. This ensures that the grease is more evenly spread in the grease reservoir and prevents the formation of air bub- bles. 9. Top the grease reservoir up to the "Maximum" marking (2). See section "5.4.2. Lubricants, fuels and filling capacities" on page 5-14 for the type of grease to be used. NOTE The reservoir must not be topped up beyond the "Maximum" marking, otherwise the compensation hole (4) will be blocked. A vacuum is caused in the grease reservoir as the grease level drops if there is a blockage in the compensation hole.
This can result in a fault in the lubrication circuit. 10. After topping up, remove the high-pressure grease gun noz- zle from the filler nipple and put the protective cap back on the filler nipple. 11. Upon completion of the lubrication cycle, check whether fresh grease has emerged at all lubrication points. If not, press but- ton (5) on the pump again so that another lubrication cycle is carried out. Repeat this process as long as necessary until fresh grease has emerged at all lubrication points. 12. Check the distribution and line system regularly for leaks and damage (breakage, buckled lines). 5-38 3 2 4 1 5