5.8. Service procedure Maintenance 19. Check that the hydraulic oil is at the correct level. For details, see section "Checking the oil level in the hydraulic tank, adding oil" on page 5-46. 20. Check that there is no leakage of oil from the filter cover mount. Replacing the hydraulic tank breather element Immediately after machine operation, the oil is hot. There- fore, wait for the oil to cool down before changing it. When removing the oil filler cap, turn it slowly to release the inter- nal pressure, then remove it carefully. 1. Remove the cap of oil filler port (F). 2. Remove the snap ring on breather (1), then remove the breather cap. 3.
Replace the filter element, then re-install cap and snap ring. 4. Tighten the cap of oil filler port (F). 5. Clean off any mud, dirt, or dust from around the breather (on top of the tank). NOTE If there is mud or dirt around the breather, the breather will not be able to function properly, and this will have and adverse effect on the hydraulic equipment. Clean the area around the breather also when replacing the breather. It is possible to replace the element with the breather installed in the tank. However, if the breather is removed, do not wrap the taper thread of the breather with seal tape before its re-assembly, and do not re-tighten too hard. 5-68 WARNING WARNING 1 F GK100592