Komatsu — Clean engine breather element

5.8. Service procedure Maintenance Clean PPC circuit strainer 1. Remove flange (1). 2. Remove strainer case (2), take out the strainer, wash it in clean diesel oil. 3. Assemble the strainer to strainer case (2), then install with flange (1). Clean engine breather element The parts and oil are at high temperature immediately after the engine has been stopped, and there is danger of burns, so wait for the temperature to go down before starting the operation. When using compressed air, there is danger that dust may fly and cause personal injury. Always wear protective glasses, dust mask, or other protec- tive clothing. 1. Remove breather (1). 2.

Wash the breather in clean light oil, then dry it with com- pressed air and install it again. 3. Coat the installing surface with liquid gasket and install breather (1). Before remove the breather, clean around the breather to remove dirt. 5-70 2 Strainer 1 GK100598 WARNING WARNING 1 GK100590