7.2. Auto positioning Special equipment and attachments 7.2.1. Auto positioning control After pressing the RAISE/LOWER select button (6) the control lamps (5 and 7) will illuminate in the following combinations. 1 3 Press two times (5) Raise off; (7) Lower on Press one time (5) Raise on; (7) Lower off Press three times (5) Raise on; (7) Lower on 5 Press four times (5) Raise off; (7) Lower off 6 7 This enables the auto positioning mode to be configured. GK100767 Example: Press selector button (6) 3 times. The boom automatically moves to the upper and lower hold posi- tions. 1. The system is switched on by pressing the RAISE/LOWER button (6).
The control lamps for the holding points (5 and 7) are illuminated. 2. If the boom control lever is moved from the HOLD (A) position to the RAISE (B) position the boom is raised until it reaches the full lift position. The control lamp (3) for the full lift position illuminates. B A Shortly before the boom reaches its full lift position, it is braked and held at a pre-set position. At the same time the control lever is returned to the HOLD (A) position. C D 3. If the boom control lever is moved from the HOLD (A) position to the LOWER (C) position the boom is lowered until it reaches the lowest end position. The control lamp (1) for the lower end position illuminates.
AE061370 Shortly before the boom reaches its lower end position, it is braked and held at a pre-set position. At the same time the control lever is returned to the HOLD (A) position. 7-6