Komatsu — 7.2.3. Auto positioning calibration

7.2. Auto positioning Special equipment and attachments 7.2.3. Auto positioning calibration Always perform an auto positioning calibration after the working attachment or the potentiometer has been replaced. 1. Use the control lever to raise the boom to the highest posi- tion. 4 3 2 1 2. Once the boom has reached the highest position, press the LOWER POSITION button (2) and the UPPER POSITION button (4) at the same time. Hold the button down for at least three seconds. 5 3. After the control lamps (1) and (3) have been on for approx. two seconds release the buttons (2) and (4). The calibration function is switched on.

6 GK100767 7 If the control lamps (1) and (3) go out the calibration is over. The settings are stored. NOTE If the control lamps (1 and 3) start flashing when step 3 is performed, the potentiometer’s output signal is not within the usual measuring range. Where this is the case the potentiometer has to be fastened in a different man- ner. After doing so perform steps 1 to 3 again. If the boom has been replaced or the auto positioning does not function correctly please get in touch with your local Komatsu dealer. 7-8