1-25 Bleeder plug BLEEDING AIR FROM FUEL SYSTEM Priming pump 1. Place a container to receive the discharged fuel under the tip end of the hose connected to the fuel filter. 2. Free the priming pump by rotating it counterclockwise. 3. Apply a pressure by operating the priming pump up and down, and bleed air by loosening the bleeder plug. 4. Tighten and fix the priming pump while holding it. 5. Wipe the fuel from the neighboring area.