EPA07/10 DD PLATFORM WORKSHOP MANUAL - ENGINE 24.1 REPLACING OIL PLUG WITH OIL SAMPLE VALVE Replace oil plug with oil sample valve as follows: 1. Using a 17 mm Allen tool remove the Allen head plug from the oil priming port on the oil coolant module. 2. Install the oil sample valve onto the oil coolant module. Torque to 80 N·m (59 lb·ft). All information subject to change without notice. DDC-SVC-MAN-0081 2010 Copyright © 2010 DETROIT DIESEL CORPORATION 24-3