Detroit Diesel DD13 DD15 DD16 — Print Preview - C:\DOCUME~1\jcampb01\LOCALS~1\Temp\.aptcache\man81000\man81

6.4 INSTALLATION OF THE DD15 & DD16 WATER MANIFOLD 6.4 INSTALLATION OF THE DD15 & DD16 WATER MANIFOLD Install as follows: NOTICE: Ensure when installing the connecting pipe, that the pipe is lubricated with clean oil. see Figure 6-1 If it is not lubricated, the connecting pipe cannot be fully installed and the rubber can be cut. NOTICE: Do not use sealant when installing water manifold to the cylinder head. 1. Install water manifold gaskets and connecting pipe onto the water manifold. 2. Install six lower water manifold bolts and start by a few threads. 3. Install water manifold onto cylinder head. 4. Install eleven upper water manifold bolts. 5.

Torque the water manifolds bolts to 30 N·m (22 lb·ft), using the torque sequence illustrated below. 6. Install EGR cooler to water manifold and torque to 20 N·m (15 lb·ft). All information subject to change without notice. 6-8 DDC-SVC-MAN-0081 2010 Copyright © 2010 DETROIT DIESEL CORPORATION