Bobcat 325/328 Excavator — 6902610-325-328 om 3-06(8).book

DELUXE INSTRUMENT PANEL SETUP (CONT’D) Job Clock Password Lockout Feature The JOB CLOCK can be set to record accumulated hours for a particular job. This allows the operator to unlock the password feature so that a password does not need to be used every time you start the engine. Press and release the HOURS/JOB/RPM button (Item 4) until JOB light is ON at the top, centre of the LCD (Item 5) [Figure SA-2] . Perform Password Entry. (See Password Entry (For Starting and Operating the Machine) on Page 94.). The password entry can be performed with the engine off or with the engine running.

While the JOB light is ON, press and hold the HOURS/ JOB/RPM button (Item 4) [Figure SA-2] until the LCD returns to zero. Figure SA-2 This process will clear the accumulated hours and will begin recording JOB CLOCK time again. (This does not affect the HOURMETER which continues to record the total operating hours of the Excavator.) Press the HOURS/JOB/RPM button again or press the START button to return the LCD to HOURMETER function. RPM The LCD (Item 5) [Figure SA-2] can be set to display engine RPM. With the engine running, press and release the HOURS/ JOB/RPM button (Item 4) until RPM light is ON at the top, centre of the LCD (Item 5) [Figure SA-2] .

Press the Lock/Unlock button (Item 1) [Figure SA-2] . The LCD will continuously alternate from UnLoc to CodE for 1 second periods. Engine RPM is now displayed in the LCD. Press the HOURS/JOB/RPM button (Item 4) [Figure SA-2] again the return to HOURMETER function. Perform Password Entry again. UnLoc will appear in the LCD (Item 5), the Unlocked Icon (Item 2) will appear in the Icon Display Area (Item 3) [Figure SA-2] and there will be two short beeps. To start an Unlocked system, press the ENTER CODE button and press the START button. When you stop the engine with the system unlocked, you will hear one long beep every 3 seconds for 15 seconds.

To lock the system again, press the Lock/Unlock button (Item 1) [Figure SA-2] and enter the password during the 15 second period. 325/328 Excavator 95 Operation and Maintenance Manual 4 5 2 1 3 B-15819 B-15819