trouble.fm Page 107 Tuesday, July 11, 2006 10:38 AM Cylinder Head Oil Passage Leak Check — Out of Chassis 4. Bolt the modified bracket with air fitting to the cylinder head over the oil supply passage. Refer to Figure 100. 5. Immerse the cylinder head in water. Heat the water and cylinder head to 150 ° F (66 ° C). 1. Remove the cylinder head from the engine. 6. Apply up to 50 psi (345 kPa) air pressure to the air fitting adapter installed in the rocker arm oil passage. Check for air bubbles. The formation of air bubbles indicates internal leakage between the cylinder head oil passage and the water jacket. 2. Install a suitable plug to seal the rocker arm oil passage at deck side of the head.
There are two ways to plug the hole: Drill and tap the oil passage to accept a pipe plug. Insert a suitable rubber plug and clamp the plug in position with a C-clamp. 3. Install an air fitting in the rocker arm passage in the top of the head. Use a discarded rocker arm bracket with an oil feed passage. Cut the bracket through the rocker arm shaft bore parallel to the mounting base surface. Drill and tap the oil supply passage to accept an air fitting. Do not exceed 50 psi (345 kPa). Damage to seals or cup plugs may result. 100 Figure 100 — Cylinder Head Oil Passage Leak Check (Out of Chassis) Page 107 TROUBLESHOOTING 1. Modified Bracket with Air Fitting 2. Plug (Pipe or Rubber)