Bobcat Company 442 — Poor A/C Performance

BASIC TROUBLESHOOTING Figure 70-80-8 Poor A/C Performance Start the excavator. Engage the A/C system with the blower fan on high. Run the excavator at full RPM for approximately 15 minutes, with the cab door closed. Figure 70-80-6 EARLY MODELS 1 N-22411 Check the temperature at the louvers (Item 1) [Figure 70-80-6] and [Figure 70-80-7] with a thermometer [Figure 70-80-8] . The louver temperature should be between 36-53 ° F. (2,2 -11,6 ° C) depending on the amount of humidity in the air. P-32675 If louver temperature is too high see the System Troubleshooting Chart.

((See SYSTEM TROUBLESHOOTING CHART on Page 70-100-1.).) Figure 70-80-7 1 LATER MODELS 1 Check the fan for proper operation or noise, and replace if necessary. ((See HEATER/AC FAN on Page 70-20-1.).) Check the air conditioning compressor belt tension. ((See AIR CONDITIONING COMPRESSOR BELT (S/N 522311001 & ABOVE) on Page 10-150-1.) or (See AIR CONDITIONING COMPRESSOR BELT (S/N 528911001 & ABOVE AND S/N 528611001 & ABOVE) on Page 10- 151-1.).) Check the A/C evaporator coil for dirt or mud, and clean if necessary.

((See Cleaning The A/C Evaporator Coil & Heater Coil (S/N 522311001 & Above) on Page 70-80-2.) or (See Cleaning The A/C Evaporator Coil And Heater Coil (S/N 528911001 & Above And 528611001 & Above) on Page 70-80-3.).) P-58141 Inspect the sight glass located on the receiver/drier for air bubbles. ((See COMPONENTS (S/N 522311001 & ABOVE) on Page 70-50-1.) or (See COMPONENTS (S/N 528911001 & ABOVE AND 52864001 & ABOVE) on Page 70-51-1.).) Check the engine coolant to see if it is bypassing the heater valve. ((See Engine Coolant By-Passing The Heater Valve on Page 70-80-15.).) 442 Excavator 70-80-1 Service Manual