BASIC TROUBLESHOOTING (CONT’D) Figure 70-80-19 Checking The Electrical System (Cont’d) Figure 70-80-18 1 2 3 1 P-63619 If the above voltages and continuity checks are OK, but the problem still persists, replace the A/C relay (Item 1) [Figure 70-80-19] . P-63617 With a multimeter, check the voltage at the excavator A/C relay connector terminals [Figure 70-80-18] . Check to see if the compressor clutch is engaging. The voltage at Pin 30 (Item 1) [Figure 70-80-18] (Yellow Wire) should be 12 volts at all times. With a person in the operator seat and the cab door open, turn the key switch to RUN, without starting the excavator. If there is no voltage check the fuse #F8, at the fuse box.
(See [Figure 70-80-16 on Page 5] or [Figure 70-80-17 on Page 5] . If the fuse is OK, refer to the electrical diagram to trace the yellow wire to its source. The voltage at pin 85 (Item 2) [Figure 70-80-18] (Brown Wire) should be 12 volts when the ignition key is in the ON position. If there is no voltage check the fuse #FA at the fuse box. (See [Figure 70-80-24 on Page 8] ) If the fuse is OK, refer to the electrical diagram to trace the brown wire to its source. Pin 86 (Item 3) [Figure 70-80-18] (Green Wire) is the ground wire. Check for continuity at Pin 86 to ground. If there is no continuity trace the green wire to its source using the electrical diagram.
442 Excavator 70-80-6 Service Manual