Bobcat Company 442 — Reclamation Procedure

SYSTEM CHARGING AND RECLAMATION (CONT'D) Reclamation Procedure (Cont'd) WARNING Remove the protective cap and connect the Refrigerant Identifier to the low pressure hose. HFC 134A refrigerant can be dangerous if not properly handled. Liquid 134A may cause blindness if it contacts the eyes and may cause serious frostbite if it contacts the skin. Gaseous 134A becomes lethal (phosgene) gas when it contacts open flame or very hot substances. NEVER SMOKE when there is the possibility of even small amounts of 134A in the air.

Any servicing work that involves release or addition of 134A to the system must be done by a competent refrigeration dealer who has the proper equipment, knowledge, and experience to service refrigeration equipment. Connect the Refrigerant Identifier to its power source. Follow the steps displayed on the refrigerant identifier screen. Allow two minutes for the refrigerant identifier to display the type of refrigerant and air content. An alarm will sound if potentially flammable hydrocarbons are present and will also indicate on the visual display. Disconnect the refrigerant identifier from the excavator A/ C.

W-2373-0500 If the refrigerant is dangerous or flammable, it must be evacuated from the A/C system into a separate container and properly and safely disposed of. Figure 70-130-56 If R134a is found, evacuate the system. IMPORTANT: Only A/C trained technicians should perform the reclaiming and recharging procedure. N-22291 Use an approved recovery/charging unit [Figure 70-130- 56] to evacuate the system. Connect the reclaimer to the excavator A/C charge ports. 442 Excavator 70-130-2 Service Manual