Bobcat Company 442 — Removal And Installation

CONDENSER (S/N 522311001 & ABOVE) Figure 70-150-2 Removal And Installation 2 Open the right side cover. Remove the refrigerant from the A/C system. (See SYSTEM CHARGING AND RECLAMATION on Page 70- 130-1.) 1 Mark the A/C hoses for correct installation. Figure 70-150-1 P-36867 1 Remove the bolt (Item 1) [Figure 70-150-2] and washer. Remove the mount (Item 2) [Figure 70-150-2] . Figure 70-150-3 P-36866 1 Remove the top hose (Item 1) [Figure 70-150-1] . Plug the hose with a proper A/C plug. WARNING In the event of a leakage, wear safety goggles. Escaping refrigerant can cause severe injuries to eyes. In contact with a flame, R134a refrigerant gives a toxic gas.

P-36868 Remove the bottom hose (Item 1) [Figure 70-150-3] . Plug the hose with a proper A/C plug. W-2371-0500 442 Excavator 70-150-1 Service Manual