Bobcat Company 442 — Evaporator Unit Removal And Installation

UPGRADED AIR CONDITIONING SYSTEM Figure 70-210-4 Evaporator Unit Removal And Installation Discharge the A/C system. (See SYSTEM CHARGING AND RECLAMATION on Page 70-130-1.) WARNING In the event of a leakage, wear safety goggles. Escaping refrigerant can cause severe injuries to eyes. In contact with a flame, R134a refrigerant gives a toxic gas. P-32701 1 W-2371-0500 HFC 134A refrigerant can be dangerous if not properly handled. Liquid 134A may cause blindness if it contacts the eyes and may cause serious frostbite if it contacts the skin. Gaseous 134A becomes lethal (phosgene) gas when it contacts open flame or very hot substances.

NEVER SMOKE when there is the possibility of even small amounts of 134A in the air. Any servicing work that involves release or addition of 134A to the system must be done by a competent refrigeration dealer who has the proper equipment, knowledge, and experience to service refrigeration equipment. Remove the floormat (Item 1) [Figure 70-210-4] . Figure 70-210-5 1 1 W-2373-0500 2 Figure 70-210-3 1 P-33790 Remove the five screws (Item 1) and right console front cover (Item 2) [Figure 70-210-5] . 1 P-32712 Turn the battery switch (Item 1) [Figure 70-210-3] to the off position. 442 Excavator 70-210-1 Service Manual