HYDRAULIC PISTON PUMP (S/N 522311001 & ABOVE) (CONT’D) Figure 1 Testing Information 3 2 The testing of the piston pump must be done in the following order: 1 Torque limiter supply pressure Pump margin pressure Load sense relief valve Torque Limiter All testing is done with the hydraulic oil at 122° to 140° F (50° to 60° C) . 5 4 6 P-40568 Check and adjust as needed the engine high idle before any hydraulic testing. Order the following parts from your Bobcat dealer: The hydraulic hoses, tubelines and fittings on the 442 Excavator are 24 ° DIN cone metric fittings. Item 1 [Figure 1] : Female 24 ° DIN to male 37 ° JIC flare Bobcat P/N 6698092.
To test the torque limiter, order the following parts to adapt the metric fittings to 37 ° JIC flare fittings: Item 2 [Figure 1] : Male 24 ° DIN to male 37 ° JIC flare Bobcat P/N 6698093. Item 3 [Figure 1] : Female 37 ° JIC flare cap Bobcat P/ N 36K-8. Item 4 [Figure 1] : 37° JIC flare union, Bobcat P/N 45KN- 8. Item 5 [Figure 1] : Nut Bobcat P/N 86F-8. Item 6 [Figure 1] : Hydraulic reservoir cover, Bobcat P/N 5 380 660 846. MEL1610 Hose Kit (not shown). 442 Excavator 20-50-4 Service Manual