HYDRAULIC PISTON PUMP (S/N 522311001 & ABOVE) (CONT’D) Torque Limiter Valve Removal and Installation Clean the outside of the pump with clean solvent and dry with compressed air before removing any components from the pump. Figure 20-50-46 1 2 P-35319 Remove the tubeline (Item 1) [Figure 20-50-46] from the pump control and torque limiter vale. NOTE: Mark the tubeline for correct installation. Loosen and remove the two mount bolts (Item 2) [Figure 20-50-46] from the torque limiter valve. Installation: Tighten the mount bolts to 7.0-7.5 ft.-lb. (9,5-10,5 N•m) torque. Figure 20-50-47 1 P-35330 Remove the torque limiter (Item 1) [Figure 20-50-47] from the pump.
442 Excavator 20-50-20 Service Manual