HYDRAULIC GEAR PUMP (S/N 522311001 & ABOVE) Figure 20-51- 2 Removal And Installation 1 IMPORTANT When repairing hydrostatic and hydraulic systems, clean the work area before disassembly and keep all parts clean. Always use caps and plugs on hoses, tubelines and ports to keep dirt out. Dirt can quickly damage the system. I-2003-0888 2 P-33806 Open the rear cover. (See Opening And Closing The Rear Cover on Page 10-40-1.) Remove the supply hose (Item 1) [Figure 20-51- 2] . Open the right side cover. (See Opening And Closing The Right Side Cover on Page 10-41-1.) Remove the hose (Item 2) [Figure 20-51- 2] .
Figure 20-51-1 Figure 20-51- 3 2 P-33805 1 1 2 P-33807 Remove the hose (Item 1) [Figure 20-51-1] . Remove the tee fitting (Item 1) [Figure 20-51- 3] . Remove the three mount bolts (Item 2) [Figure 20-51- 3] Installation: Tighten the bolts to 22-26 ft.-lb. (30-35 N•m) torque. Remove the pump. 442 Excavator 20-51-1 Service Manuall