HYDRAULIC GEAR PUMP (S/N 522311001 & ABOVE) (CONT’D) Figure 20-51- 9 Disassembly (Cont’d) Figure 20-51- 7 2 1 P-33813 1 1 Remove the O-ring (Item 1) [Figure 20-51- 9] from the pump. P-33809 Figure 20-51- 10 Mark and remove the bolts (Item 1) and remove the supply line fitting (Item 2) [Figure 20-51- 7] . 1 NOTE: Two different bolt lengths are used. Mark the bolts before removal for correct installation. 2 Figure 20-51- 8 1 P-33987 Place the pump coupler (Item 1) [Figure 20-51- 10] in a vise that is equipped with soft jaws. Loosen the nut (Item 2) [Figure 20-51- 10] . Remove the pump from the vise and remove the nut.
P-33810 Remove the O-ring (Item 1) [Figure 20-51- 8] from the supply hose fitting. 442 Excavator 20-51-4 Service Manual