HYDRAULIC PISTON PUMP (S/N 528911001 & ABOVE AND S/N 528611001 & ABOVE) (CONT’D) Torque Limiter Valve Removal and Installation Clean the outside of the pump with clean solvent and dry with compressed air before removing any components from the pump. Figure 20-52-39 1 2 P-58599 Remove the tubeline (Item 1) [Figure 20-52-39] from the pump control and torque limiter vale. NOTE: Mark the tubeline for correct installation. Remove the bolts (Item 2) [Figure 20-52-39] from the torque limiter valve. Installation: Tighten the mount bolts to 7.0-7.5 ft.-lb. (9,5-10,5 N•m) torque. Figure 20-52-40 1 P-58601 Remove the torque limiter (Item 1) [Figure 20-52-40] from the pump.
442 Excavator 20-52-17 Service Manual