HYDRAULIC GEAR PUMP (S/N 528911001 & ABOVE AND S/N 528611001 & ABOVE) Figure 20-53-2 Removal And Installation Drain the hydraulic reservoir. (See Replacing The Hydraulic Oil on Page 10-100-2.) 1 Remove the muffler and muffler mount. (See Removal And Installation on Page 60-21-1.) 1 IMPORTANT P-58490 When repairing hydrostatic and hydraulic systems, clean the work area before disassembly and keep all parts clean. Always use caps and plugs on hoses, tubelines and ports to keep dirt out. Dirt can quickly damage the system. Remove the 4 bolts (Item 1) [Figure 20-53-2] and the hose. I-2003-0888 Figure 20-53-3 Figure 20-53-1 1 1 1 1 P-58491 P-58489 Remove the 2 bolts (Item 1) [Figure 20-53-3] .
Remove the 4 bolts (Item 1) [Figure 20-53-1] and remove the hose. Installation: Apply thread adhesive (Loctite™ 242) to the bolt threads. Tighten the bolts to 48-55 ft.-lb. (65-75 N•m) torque. Remove the pump. 442 Excavator 20-53-1 Service Manuall