OIL TEMPERATURE REGULATOR Figure 20-210-1 Description 1 The oil temperature regulator, when closed, diverts hydraulic oil from the oil cooler to the hydraulic tank. The regulator opens at 131° F (55° C) allowing oil to flow through the cooler then to tank. 3 Removal And Installation Drain the hydraulic reservoir. (See Replacing The Hydraulic Oil on Page 10-100-2.) 1 2 Remove the air cleaner. (See AIR CLEANER on Page 60-30-1.) P-33728 IMPORTANT Remove the 2 tee fittings (Item 1) [Figure 20-210-1] . Remove the hose (Item 2) [Figure 20-210-1] . When repairing hydrostatic and hydraulic systems, clean the work area before disassembly and keep all parts clean.
Always use caps and plugs on hoses, tubelines and ports to keep dirt out. Dirt can quickly damage the system. Remove the 2 bolts (Item 3) [Figure 20-210-1] . Installation: Tighten the bolts to 6-7 ft.-lb. (8-10 N•m) torque. I-2003-0888 Remove the valve. 442 Excavator 20-210-1 Service Manual