ALTERNATOR (CONT'D) Figure 50-30-22 Rectifier Continuity (Diode) Test NOTE: The photos may appear different. The procedure is the same. Figure 50-30-20 P-63613 1 Reverse the ohmmeter leads. Read the ohmmeter. There must be resistance in one direction and an open in the other. If the readings are the same, replace the rectifier bridge. Repeat this step for the other diodes [Figure 50- 30-22] . 2 P-63611 Unsolder the stator coil at the connections (Item 1) to the rectifier bridge. Remove the stator (Item 2) [Figure 50- 30-20] . Figure 50-30-23 NOTE: Bend phase lead-out wires as little as possible. Figure 50-30-21 1 2 1 P-63615 Check the negative diodes in the rectifier bridge.
Connect the negative lead of the ohmmeter to the surface of the diode plate (Item 1) that is not painted. Connect the positive lead of the ohm meter to one of the leads for the negative diodes (Item 2) [Figure 50-30-23] The negative diodes are the diodes on the side of the rectifier bridge opposite the B+ terminal. 2 P-63612 Test the positive diodes in the rectifier bridge. Connect the negative lead of the ohmmeter to the output B+ terminal (Item 1). Connect the positive lead of the ohm meter to one of the leads (Item 2) [Figure 50-30-21] for the positive diodes. The positive diodes are the diodes closest to the B+ terminal. 442 Excavator 50-30-8 Service Manual