The Charles Machine Works, Inc. HT220 — 100 Hour

HT220 Operator’s Manual Service - 105 100 Hour Check Breathers Check breathers (shown) every 100 hours. Check that there are no obstructions or sediment build-ups. Clean the breathers in case of obstructions. Use an oil-based solvent. Do not carry out the operation using flammable solvents or standing near a fire, sparks or other flammable sources. Check Track Tension Check track tension every 10 hours. Correct tension (A) is 3/8” (10 cm) chain sag between the conveyor rollers. If distance (A) is greater than 3/8” (10 cm), see“Adjust Track Tension” on page 118.