Service - 90 HT220 Operator’s Manual 10 Hour Check Emergency Stop Test function of each emergency stop buttons (shown) every 10 hours. See “Start After Emergency Stop” on page 57. 1. Turn ignition switch to the on position but do not start the engine. 2. Press an emergency stop button. See “Start After Emergency Stop” on page 57. 3. Repeat process for each emergency stop button. Service machine as required. Lube Torque Post Lube Cab Door Hinges Lube cab door hinges with MPG every 10 hours. 10 hours.