The Charles Machine Works, Inc. HT220 — 10 Hour

Service - 100 HT220 Operator’s Manual 10 Hour Check Chain Baseplates and Tooth- stops The machine is equipped with specific-width tooth-stop plates (1). The tooth-stop plates and pockets are provided with a hard metal coating in their easily-worn parts. This coating must always be preserved to guarantee the life of the tooth-stop pocket plates. The machine operator must take note of the hardened parts and preserve them. The antirollover plates (not provided on the narrow chain) are originally installed on the tooth-stop plates. The machine operator must overhaul these plates.

During assembly, make the plates touch the ground in ascending order (from the right side, in clockwise ascending order) and by turning their teeth toward the digging direction. Check the screws (3) and the locknuts (2) of the chain plates regularly. Use only high-tensile screws, nuts and washers (8 grade). Check plate nuts and screws daily. Their loosening may cause the chain to break and the plate to get damaged. Check Boom and Wearplates Check wearplates every 10 hours. These plates (shown) must be replaced periodically in order to avoid damage to the boom and to the excavation material internal recess.

If the wearplate is worn out to the extent that the digging chain “nicks” the boom, the wearplate must be “rotated” or replaced. A hard metal coating applied to the severest wear position will extend the plate life. See “Replace Wearplate” on page 120.