SECTION 6 SPECIFICATIONS Page 8 SPECIFICATIONS 6.3.8. OPERATION WEIGHTS (approximate) A machine with mounted equipment (hydraulic tilt), operator, full fuel tank and standard equipment: TD-15H TD-15H-LT Blade Semi-U Semi-U R.O.P.S. 19850 [kg] 20150 [kg] Cab with A/C and ROPS 20250 [kg] 20550 [kg] 6.3.9. ELECTRIC SYSTEM System voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 [V], negative ground Batteries (maintenance-free) . . . . . . . . . . . . . . . . . . . . . . . . . . . . two 12 [V] Alternator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 [A] 6.3.10.
FUEL CONSUMPTION During intensive slot dozing tests in sandy soil (soil density app. 1.89 [t/m 3] ) the average fuel consumption amounted to app. 37 [l/h]. Average operational fuel consumption. The above specified fuel consumption value refers to a short period of intensive operation of the machine only. However, taking into consideration actual longer periods of machine operation fuel consumption value is considerably lower and can be estimated at the level of app. 28 [l/h]. 6.4.
SPECIAL TORQUES DRESSTA TD-15H No Description of tightening place Size of thread Torque [Nm] No of places 1 Main Harness to Pod at Rear of LH Console 4-40 0.7 4 2 Horn Switch Terminal (On RH Console) 8-32 1.8-3.4 2 3 Neutral Start & Engine Shutdown Switch Terminal 8-32 2 4 4 Back-up Alarm Terminal 8-32 2 2 5 Back-up Alarm Switch Terminal (In Console) 8-32 2 2 6 Cab Dome Light Mounting Screw 10-24 2 2 7 Transmission Filter Warning Light Switch 10-24 1.4-1.8 2 8 Hydraulic Filter Warning Light Switch 10-24 1.4-1.8 1 9 Cooling Temperature Sensor Terminal 10-32 2 1 10 Circuit Breaker Mounting Screw (On Hood Support) 10-32 2 2 11 Circuit Breaker Mounting Screw (On Instrument Panel) 10-32 2 10