Komatsu — 24.6 EVERY 250 HOURS SERVICE

24. SERVICE PROCEDURE 24. SERVICE PROCEDURE 24.6.5 CHECK FAN BELT AND ALTERNATOR BELT TENSION, ADJUST Checking The belt should normally deflect by about 3 mm (0.12 in) when pressed with the finger (with a force of approx. 6 kg (13 lb) at a point midway between the alternator pulley and fan pulley. Tensile force when using tension gauge: 60 – 65 kg (132.3 – 143.3 lb) Approx. 3 mm (0.12 in) Alternator pulley AM091620 Water pump pulley Fan pulley AM091630 Adjusting 1. Loosen locknut 1 and bolts 2 and 3 , then adjust the belt tension with adjustment bolt 4 . 2. After adjusting, tighten bolts 2 and 3 , turn adjustment bolt 4 back 1/2 turns, then tighten locknut 1 . Tightening torque Locknut 1 :

6.75 ± 0.75 kgm (48.8 ± 5.4 lbft) Bolt 2 , 3 : 11.25 ± 1.25 kgm (81.4 ± 9.0 lbft) AM091640 3. Check for damage to the pulleys, and wear of the groove and belt. Be particularly careful to check that the belt is not in contact with the bottom of the groove. 4. If the belt has stretched and there is no allowance for adjust- ment, or if it is cut or cracked, replace the belt. 5. After replacing the belt, operate for one hour, then adjust again. 3-54