Kaiyi HL940 — Kaiyi HL940 User Manual

10. 10. PILOT CONTROL VALVE P PILOT CONTROL VALVE P RESSURE TEST RESSURE TEST В SPECIFICATION SPECIFICATION Oil temperature 45 Ь 5 C (113 Ь 9 F) Engine speed Low idle Begin metering 1/4" of lever travel Pressure in detent : Boom float detent 2.5 MPa (25 bar ) Pressure at feel position : Boom power down 22~25 bar Boom raise 22~25 bar Bucket rollback 22~25 bar Bucket dump 22~25 bar GAUGE AND TOOL GAUGE AND TOOL Gauge 0~7 MPa (0~70 bar , 0~1000 psi ) В As the control lever is moved from neutral, the pilot pressure will suddenly jump up to approximately 6.5 bar at 1/4 in . travel.

The pressure should then increase smoothly to the specification at the FEEL position (or 3/4 lever travel), and then jump up about 510 psi as the lever is moved into detent. P This test will determine if adequate pilot pressure is available to move the loader control valve spools. The FEEL position is when lever is moved to feel the ramp of the detent before lever passes into detent position. ц Safety valve 1) Lower boom to ground. 2) Connect gauge to the pilot pressure port of function to be checked. 3) Install temperature reader (see temperature reader installation procedure in this group). 4) Heat hydraulic oil to specification (see hydraulic oil warm up procedure in this group).

75796WE32 Run engine at specification. Activate function to be checked and record pressure reading. If boom raise or bucket rollback FEEL positions are not operation due to boom or bucket position, plug boom float detent wires into bucket leveler solenoid or boom height kickout solenoid. This will provide a feel position on the control lever. 5) ц 6-64