MAINTENANCE SCHEDULE CHART MAINTENANCE. MAINTENANCE WHEN USING HYDRAULIC BREAKER For machines equipped with a hydraulic breaker, the hydraulic oil deteriorates faster than for normal bucket digging operations, so set the maintenance intervals as follows. Replacing hydraulic filter element On new machines, replace the element after the first 100 to 150 hours, then carry out further replacement of the element according to the table on the right. Replacement interval (H) Replacement interval for hydraulic oil Changing oil in hydraulic tank Change the oil according to the table on the right.

(When not using breaker) Breaker operation (ratio %) Hydraulic Fillerelement AD31373D (When using breaker only USE OF BIO-DEGRADEABLE OIL Special care must be taken when using bio-degradable oil in the hydraulic system of the hydraulic excavator. When the machine is supplied from the factory with bio-degrad- able oil, the following change intervals should be used. The oil supplied from the factory is classed as BO46-G3. (If the machine has been filled with any other type of bio-degradable oil, then con- tact your Komatsu distributor for advice on change intervals). Filter changes 1. The first filter change should be made 50 hours after first use. 2.

The second, and subsequent changes should be made at the standard changing intervals. 3. If an abnormality is found in the characteristics of the oil, change the filter immediately. Oil changes 1. Change the bio-degradable oil every 2500 hours. 2. If an abnormality is found in the characteristics of the oil, change the oil immediately. 190