SERVICE PROCEDURE MAINTENANCE. WHEN REQUIRED CHECK, CLEAN AND REPLACE THE AIR CLEANER ELEMENT Never clean or replace the air cleaner element with the engine running. When using pressured air to clean the element, wear safety glasses or goggles to protect the eyes. Checking If air cleaner clogging monitor flashes, clean the air cleaner ele- ment. AD313740A Cleaning or replacing the outer element 1. Open the machine door, loosen wing nut (2), then remove cover (6). Remove wing nut, then take out element (7). 2. To prevent dirt or dust from entering, use tape or a clean cloth to cover the inner element of the air cleaner body. 3. Clean the air cleaner body interior and the cover. 4.
Direct dry compressed air (less than 700 kPa (7 kg/cmІ)) to element (7) from inside along its folds, then direct it from out- side along its folds and again from inside. Remove one seal from the outer element whenever the outer element has been cleaned. Replace the outer element which has been cleaned 6 times repeatedly or used throughout a year. Replace the inner element at the same time. Replace both inner and outer elements when the monitor lamp (3) flashes soon after installing the cleaned outer element (even if it has not been cleaned 6 times). 192 WARNING 7