Komatsu — CHECK ALTERNATOR

MAINTENANCE. SERVICE PROCEDURE FAN Personal injury can result from a fan blade failure. Never pull or pry on the fan. This can damage the fan blade(s) and cause fan failure. Check the fan for cracks, loose rivets (for metal fans) and bent or loose blades. Make sure it is securely mounted. Tighten the cap- screws if loose. Replace damaged fans. CHECK AND TIGHTEN WHEEL NUTS Order for tightening Tighten the bolts in the order shown in the diagram. Torque to 450 Nm. CHECK ELECTRICAL INTAKE AIR HEATER Before the start of the cold season (once a year), contact your Komatsu distributor to have the electrical intake air heater repaired or checked for dirt or disconnections.

CHECK ALTERNATOR GENERAL The alternator requires no lubrication since its bearings are fac- tory lubricated for life and require attention only at the time of major overhaul. The alternator is equipped with an integral, transistorized voltage regulator. If the alternator fails to operate properly, consult your distributor. PRECAUTIONS NOTE: The unit electrical system is negative ground. Be CER- TAIN the ground polarity is correct when: 199 WARNING