Komatsu — CLEAN FRESH AIR INTAKE FILTER

SERVICE PROCEDURE MAINTENANCE. CHECK OIL LEVEL IN SWING MACHINERY CASE, ADD OIL The oil is at high temperature immediately after the machine has been operated. Wait for the oil to cool down before carrying out this check. 1. Remove dipstick (G) and wipe the oil from the dipstick with a cloth. 2. Insert dipstick (G) fully in the guide. 3. When dipstick (G) is pulled out, if the oil level is between the H and L marks of the gauge, oil level is proper. 4. If the oil does not reach the L mark on dipstick (G), add engine oil through dipstick insertion hole (F). When refilling, remove bleeding plug (1).

For details of the oil to use, see “USE FUEL, COOLANT AND LUBRICANTS ACCORDING TO AMBIENT TEMPER- ATURE” on page 177. 5. If the oil level exceeds the H mark on the dipstick, loosen drain plug (P) to drain the excess oil. 6. After checking oil level or adding oil insert the dipstick into the hole and install air bleeding plug (1). CLEAN FRESH AIR INTAKE FILTER 1. Remove two wings nuts holding retaining strap (2). 2. Grasp filter element (3) centrally and pull out of housing. 3. Note that filter element is a sandwich of a fine filter and a coarse filter. Clean filter by placing element in a mixture of hand hot water and neutral detergent with the coarse filter side downwards.

Move element up and down to release dirt. (A) Coarse (outside) (B) Fine (inside) 212