Komatsu — BELTS, GENERAL

MAINTENANCE. SERVICE PROCEDURE CHECK LEVEL OF BATTERY ELECTROLYTE To avoid gas explosions, do not bring fire or sparks near the battery. Battery electrolyte is dangerous. If it gets in your eyes or on your skin, wash it off with large amounts of water, and consult a doctor. Carry out this check before operating the machine. 1. Open the battery door on the left side of the machine. 2. Remove cap (1), and check that the electrolyte is at the spec- ified level (10 to 12 mm above the plate). If the electrolyte level is low, add distilled water to the specified level. If the battery electrolyte is spilled, have dilute sulphuric acid added. 3.

Clean the air hole in the battery cap, then tighten the cap securely. When adding distilled water in cold weather, add it before starting operations in the morning to prevent the electrolyte from freezing. LUBRICATE SWING CIRCLE (2 points) 1. Lower the work equipment to the ground. 2. Using a grease pump, pump in grease through the grease fit- tings shown by arrows. 3. After greasing, wipe off all the old grease that was pushed out. BELTS, GENERAL Before working on the engine or electrical system, disonnect the negative (ground) battery cable. Tag the cable and con- trols to warn against starting. Replace badly worn, greasy or severely cracked belts immedi- ately.

These conditions prevent the belt from functioning correctly. Prior to installing new belts, make sure all pulley grooves are clean and not worn. If a pulley is damaged or if the grooves are worn, it should be replaced. 215 WARNING WARNING