Perkins — Perkins 4.108 4.107 4.99 Diesel Engine Workshop Manual

SECTION R Engines for Refrigeration Units 4.108 engines supplied for the driving of refrigeration units are similar to those engines described in this 4.108 workshop manual and in the main, can be ser- viced in accordance with the instructions given in this publication. The following differences should however, be noted:- Lubricating System Due to the fact that the lubricating oil sump capacity has been increased to 28 pints and a much larger full flow lubricating oil filter is used, also the addition of a by-pass lubricating oil filter, the lubricating oil and filter element change period is extended to 1,000 hours. Cold Starting Procedure (Refer Figs.

R.1, R.2) Fuel System Glow plugs are fitted in the cylinder head to assist starting under cold conditions (see Page C.2). A mechanically governed fuel injection pump is fitted. The fuel pump rotor timing letter is "C", No.1 outlet is Wand static timing is 21 0 B.T.D.C. or 0.150 in (3,81mm) displacement B.T.D.C. On early engines the glowplugs are screwed into adaptors which are fitted to the cylinder head. Later engines have the glowplugs screwed directly into the cylinder head. For further information refer to page 09. Two timing holes are provided in the rear of the crankshaft pulley, which when engaged with the timing pin, denote T.D.C. and 21 0 B.T.D.C. (static timing point).

When this method of timing the fuel injection pump is used, ensure that the fuel pump circiip is correctly set. For how to set the circiip, refer to the first part of "Alternative method where no tool is available," page N.7. Cylinder Liners The cylinder liners fitted to 4.108 refrigeration unit engines can be rebored 0.020 in (0,51 mm) oversize to the standard bore dimensions given on Page 8.3. COMBUSTION CHAM GLOW PLUG ADAPTOR .+ ( GLOW PLUG , _ _ . ,---I ----J{ ._.J ---; R1 4.108 Series Workshop Manual, June 1986