Komatsu — INSTALLATION OF OPTIONAL ELECTRICAL EQUIPMENT

INSTALLATION OF OPTIONAL ELECTRICAL EQUIPMENT A: 1. Power source when installing optional electrical equipment. When installing extra electrical equipment, always take the power from connector No. M26 provided inside the panel (within 15A). Never take the power from the following terminals. It will cause the fuse to blow or will have adverse effect on the mecha- tronics equipment. 0 Fuse No. 9 0 Starting swtich terminal B, BR and ACC 0 Battery relay terminal BR Use a male connector (4 pin) to connect to the power source pick-up. 2. 3. B: Connections when adding extra lamps When adding lamps, use the connection method shown in the diagram.

* When the present lamp relay is turned ON, the standard lamps light up. At the same time, power flows to the additional relay, so the additional relay is switched on and the extra lamps light up. (a): Fuse box (b): Monitor panel (c): Lamp switch (d): Two direct relays cannot be used (e): Lamp relay (f): Additional relay (g): Standard lamps (h): Additional lamps ----- Dashed line: Additional wiring harness - 98 -