BLEEDING AIR FROM CIRCUIT When replacing or cleaning the hydraulic oil, filter element, or strainer, or when replacing or cleaning the line filter element, or when repairing or re- placing hydraulic equipment, or after removing the hydraulic piping, bleed the air from the circuit. PROCEDURE FOR BLEEDING AIR Air bleeding item Air bleeding procedure 1 2 3 4 5 6 Nature of work Bleed air start Bleed air Bleed air Bleed air from engine from pump cylinder from swing from travel op~J~& motor motor . Change hydraulic oil . Clean strainer o-O--We-o-o-o *1 *1 . Replace return filter CO element 0 . Replace, repair pump Replace, clean line filter element o-0-0 W 0 . Remove suction piping .
Replace, repair control valve o-o----o -0-o . Replace cylinder . Remove cylinder piping o-o * 0 . Remove swing motor piping 0 ,O * 0 . Replace swing motor ’ Replace travel motor, swivel * Remove travel motpr, swivel piping 0 -0-o *1 Bleed the air from the swing motor and travel motor only when the oil inside the motor case has been drained. a. Bleeding air from pump 1. Loosen the bleeder at portion (A), remove plug (B), then add oil through filler (B) to fill the pump with oil. 2. After completion of bleeding the air, install plug (B) first, then tighten the bleeder. If the bleeder is tightened first, oil will spurt out from hole (B).
If the pump is operated without the pump case being filled with hydraulic oil, abnormal heat will be generated, and this may lead to premature da- mage to the pump. Tightening torque Bleeder (A): 0.9 Z!I 0.1 kgm Plug (B): 7.0 f 1.0 kgm - 112 -