EVERY 2000 HOURS SERVICE * Maintenance for every 100, 250, 500 and 1000 hours should be carried out at the same time. a. HYDRAULIC TANK 1. Retract the arm and bucket cylinder to the stroke end, then lower the boom and put the tip of the teeth in contact with the ground. 2. Remove the cap of oil filler (F). A When removing the cap, turn it slowly to relieve inner pressure. 3. Remove drain plug (P) at the bottom of the machine to drain off the oil. After draining off the oil, tighten up drain plug (P). 4. Pour in the specified amount of engine oil through oil filler (F). 5. After adding oil, check that the oil is at the specified level. For details, see CHECK BEFORE STARTING.
Sr The type of lubricant used depends on the ambient temperature. Select according to the table “FUEL, COOLANT AND LUBRICANTS”. * Refill capacity: 195 B * When changing the oil in the hydraulic tank or replacing the main pump, or when removing the pump suction piping, bleed the air from the circuit before starting the engine. For details, see BLEEDING AIR FROM CIRCUIT. Sr If the pump is operated without filling the pump case with hydraulic oil, abnormal heat will be generated and this may lead to premature damage of the pump. * When a hydraulic breaker is installed, the hydraulic oil deteriorates much more rapidly than when carrying out ordinary digging operations with a bucket.
Therefore, change the oil according to the table. (a): Change interval (Hours) (b): (When not using breaker) (c): Breaker operation rate (%) (d): (Using only breaker) (e): Hydraulic oil change interval - 148-