Mack Trucks — PV776-21394653.pdf

Operator’s Manual Vehicle Maintenance CXU, CHU, GU, TD, MRU and LEU 67 Bio Diesel The only Bio Diesel Fuel approved by MACK Inc. for use in EPA 2010 MACK Engines is Soy Methyl Ester (SME or SOME) in blends up to B5 Concentration (5% blend). Note: Although higher concentrations are available, concentration up to B5 (maximum) are the only blends currently approved by MACK Inc. Fuel Storage If fuel is stored on site: Keep storage tank covered to prevent water entry. DO NOT use a tank made of galvanized metal or any galvanized piping for diesel oil storage. Diesel will react with the zinc, forming solids that can clog fuel filters and cause engine damage.

Fuel stored for a long time may oxidize and form solids, causing filtering problems. Keep the area around the fill cap clean. Tilt the tank slightly toward the drain plug area so water and sediment can be easily drained. Generally, fuel contamination occurs as the result of improper fuel handling. The most common types of contamination are water, dirt and microbial growth (black slime). The formation of varnishes and gums resulting from poor fuel stability or long storage (stale fuel) also affects fuel quality. The best treatment for contamination is prevention by maintaining a clean storage system and choosing a reputable fuel supplier.