. OPERATION TROUBLES AND ACTIONS 3 - 125 Engine ( ) : Always contact your Komatsu distributor when dealing with these items. In cases of problems or causes which are not listed below, contact your Komatsu distributor for repairs.
Problem Main causes Remedy Engine oil pressure monitor lights up Oil level low in oil pan (sucking air in) Clogging oil filter cartridge Defective tightening of oil pipe, pipe joint, oil leakage from damaged point Defective engine oil pressure Add oil to specified level, see CHECK BEFORE STARTING Replace cartridge, see EVERY 500 HOURS SERVICR ( Check, repair) ( Replace sensor) Steam spurts out from top of radiator (pressure valve) Coolant level low, leakage of water Loose fan belt Dirt scale accumulated in cooling system Clogging radiator fins or damages fins Defective thermostat Loose radiator filler cap (high altitude operations) Check, add coolant, repair, see CHECK BEFORE STARTING Adjust fan belt tension, see EVERY 250 HOURS SERVICE Change coolant, flush inside of cooling system, see WHEN REQUIRED Clean or repair, see EVERY 500 HOURS SERVICE ( Replace thermostat) Tightening cap or replace packing Red range of engine coolant temperature gauge lights up Engine dose not start when starting motor is turned Lack of fuel Air in fuel system Defective fuel injection pump or defective nozzle Starting motor cranks engine sluggishly Pre-heating monitor dose not light up Add fuel, see CHECK BEFORE STARTING Repair place where air in sucked in, see EVERY 500 HOURS SERVICE ( Replace pump or nozzle) See ELECTRICAL SYSTEM See ELECTRICAL SYSTEM Exhaust gas is white or blue Too mach oil in oil pan Add oil to specified level, see CHECK BEFORE STARTING Exhaust gas sometimes becomes black Combustion noise occasionally make breathing sound Defective nozzle ( Replace nozzle)